Bangalore Office
Liaison Office - Delhi
Precision LCR Meter Model 4300R – 300kHz

Product Description

The APLAB Precision LCR Meter Model 4300R Is A High-accuracy Impedance Test Instrument Designed For Precision Measurement Of Electronic Components And Materials. With A Test Frequency Extending Up To 300kHz, Six-digit Resolution, And A Basic Accuracy Of 0.05%, It Provides Detailed Measurement Capabilities For Production Quality Assurance, Incoming Inspection, And Laboratory Precision Testing.

The Instrument Supports Simultaneous Display Of Up To Four Different Measurement Parameters With Flexible Combinations. AC And DC Parameters Can Also Be Measured Simultaneously Without Interference, While The Self-demagnetization Function Supports Measurement Stability.

Flexible Test Signal And Bias Control

The Model 4300R Supports Test Frequencies From 20Hz To 300kHz With 1mHz Resolution. Test Levels Range From 10mV To 2V, While Current Levels Range From 100µA To 100mA. The Instrument Also Provides Built-in DC Bias Capabilities, Including Voltage Mode From -5V To +5V And Current Mode From -50mA To +50mA.

A Separate DC Source Provides An Adjustable Output From -10V To +10V, With Low-noise Operation. This Combination Of Test Signal And Bias Control Makes The Instrument Suitable For Detailed Characterization Of Electronic Components Under Different Operating Conditions.

Comprehensive Component Measurement

The LCR Meter Supports A Broad Range Of Measurement Parameters, Including Impedance, Resistance, Reactance, Admittance, Conductance, Susceptance, Capacitance, Inductance, Dissipation Factor, Quality Factor, Phase Angle, Percentage Deviation, And DC Resistance.

It Supports Both serial And Parallel Equivalent Modes, Along With Automatic And Hold Ranging Modes. Trigger Options Include Internal, Manual, DUT, External, And BUS Modes, Providing Flexibility For Manual Laboratory Measurements As Well As Automated Testing Systems.

Fast Measurement And Production Testing

The Model 4300R Is Designed For High-speed Testing, With Measurement Rates Of Up To 65 Measurements Per Second In Fast Mode. Medium Mode Provides 10 Measurements Per Second, While Slow Mode Provides 5 Measurements Per Second.

Its Flexible Comparator Supports Tolerance And Sequence-based Testing, Allowing Rapid Pass/Fail Determination Through Multi-parameter Testing. The Comparator Provides 10 Bins From BIN0 To BIN9, Along With NG And AUX Pass/Fail LED Indications.

Graphical Scanning And Correction

The Instrument Includes Graphical Scanning Functions For frequency, Level, Bias Voltage/current, And DC Source, Enabling Detailed Analysis Of Component Characteristics. Its List Sweep Function Supports Up To 20 Points For Frequency, Level, DC Bias, And DC Source Scanning.

The User Correction System Supports Open, Short, And Load Correction As Well As Full-frequency Correction. Up To 64 Frequency Correction Points Are Supported To Improve Measurement Consistency And Repeatability, Including Applications Involving Multi-channel Scanning.

Connectivity, Storage And Automation

The Model 4300R Provides Multiple Communication Interfaces, Including RS232C, USB-HOST, USB-CDC, USB-TMC And HANDLER, With GPIB And SCANNER Available As Options. These Interfaces Support Integration Into Automated Measurement And Production Test Systems.

Measurement Data Can Be Stored In CSV And TXT Formats, While On-screen Images Can Be Saved In BMP, PNG And GIF Formats. The Instrument Also Supports Storage And Recall Of Setup Files And USB Firmware Upgrades. Internal Storage Supports 100 Groups, While External USB Storage Supports Recalling Up To 500 Groups.

Clear TFT Display And Compact Design

The Instrument Features A 5-inch TFT LCD With 480 × 272 Resolution, Providing A Clear Interface For Measurement Results, Parameters And Testing Information. Its Compact Dimensions Are Approximately 350 × 120 × 360 Mm, With A Weight Of Approximately 3.5 Kg.

Product Specifications

Model:

APLAB Precision LCR Meter Model 4300R

Product Type:

300kHz Precision LCR Meter

Measurement Parameters:

|Z|, C, L, R, X, |Y|, B, G, D, Q, θ, DCR

Basic Accuracy:

0.05%

Test Frequency:

20Hz to 300kHz

Frequency Resolution:

1mHz

Output Impedance:

10Ω, 30Ω, 100Ω

Test Voltage:

10mV to 2V

Voltage Resolution:

1mV

Test Current:

100µA to 100mA

Current Resolution:

1µA

DC Source Output:

10mV to 1V

Internal DC Bias Voltage:

-5V to +5V

DC Bias Voltage Resolution:

1mV

DC Bias Current:

-50mA to +50mA

DC Bias Current Resolution:

20µA

Measuring Speed:

Fast 65, Medium 10, Slow 5 measurements/sec

Equivalent Mode:

Serial, Parallel

Ranging Mode:

Auto, Hold

Trigger Mode:

Internal, Manual, DUT, External, BUS

Correction Function:

Open / Short / Load, Full frequency correction, 64-point frequency correction

Graphics Scanning:

Frequency, Level, Bias Voltage / Current, DC Source

List Sweep:

20 points for frequency, level, DC bias and DC source

Display:

480 × 272, 5-inch TFT LCD

Memory:

100 groups internal and 500 groups on USB disk

Comparator:

10 bins, BIN0-BIN9, NG, AUX PASS/FAIL LED

Interfaces:

RS232C / USB-HOST / USB-CDC / USB-TMC / HANDLER / GPIB optional / SCANNER optional

Temperature Range:

0°C to 40°C

Humidity:

≤90% RH

Power Supply:

99V to 242V

Power Frequency:

47.5Hz to 63Hz

Power Consumption:

Less than 60 VA

Dimensions:

350 (W) × 120 (H) × 360 (D) mm approx.

Weight:

3.5 kg approx.

Frequently Asked Questions (FAQs)

The Precision LCR Meter Model 4300R is designed for accurate measurement and analysis of electronic components and materials. It can measure parameters such as impedance, resistance, reactance, capacitance, inductance, admittance, conductance, dissipation factor, quality factor, phase angle, and DC resistance. With a measurement frequency extending from 20Hz to 300kHz and a basic accuracy of 0.05%, it is suitable for laboratory measurements, incoming component inspection, production quality control, research, and precision component testing.

The Model 4300R supports test frequencies from 20Hz up to 300kHz, with a frequency resolution of 1mHz. This wide frequency range allows users to examine component characteristics across different operating conditions and perform detailed frequency-based analysis. The instrument also provides graphical frequency scanning and list sweep functions, making it useful for analyzing how electronic components respond to changing test frequencies.

Yes, the Precision LCR Meter Model 4300R includes built-in DC bias capabilities. Its voltage mode provides a bias range of -5V to +5V with 1mV resolution, while the current mode supports -50mA to +50mA with 20µA resolution. The instrument also provides a separate DC source output from -10V to +10V. These functions allow components to be evaluated under controlled DC bias and source conditions.

The Model 4300R is designed for high-speed component testing and can perform up to 65 measurements per second in Fast mode. It also provides Medium and Slow measurement modes at 10 and 5 measurements per second respectively. This makes the instrument suitable for applications ranging from detailed laboratory analysis to faster production-line inspection. Its automatic DUT trigger and multi-parameter comparator functions further support efficient automated testing.

Yes. The Model 4300R provides several communication interfaces for integration with external equipment and automated test systems. Standard interfaces include RS232C, USB-HOST, USB-CDC, USB-TMC, and HANDLER, while GPIB and SCANNER interfaces are available as options. The instrument also supports measurement-data storage in CSV and TXT formats and can store setup and measurement information, making it suitable for production testing, data collection, quality assurance, and automated component evaluation.